VG Estimating · Capture Form · Form 01

Property Walkthrough Site · Structure · Envelope · MEP · Interiors

Fill at
PM walkthrough
Filled by
PM
Date
2026-05-04
Status
Draft 1
Fill during or immediately after the property walkthrough. Captures coarse drivers, condition flags, and scope multipliers — anything a PM can directly observe or estimate at a rough order of magnitude. Detailed measurements move to Form 03; grade/material selections move to Form 08.
Property address
Date
PM / person capturing
Listing price / acquisition target
§ 01P1WO1a — Site Management
Feeds: P1WO1a (Site Management) · P1WO4 (Site Work)
Estimated project duration in months
months_holding
Site access condition
site_access
e.g. standard / restricted / gated
§ 02P1WO1b — Tree Removal
Feeds: P1WO1b (Tree Removal)
Number of large trees to remove
tree_removal_count
Stump grinding required
stump_grinding
e.g. yes / no
§ 03P1WO3 — Demolition
Feeds: P1WO3 (Demolition) · P1WO6 (Framing)
Asbestos / lead suspected — triggers survey
hazmat_present
e.g. yes / no / unknown
Demolition scope (partial=0.6 / selective=0.8 / full=1.0)
demo_scope
e.g. partial / selective / full
Structural condition of existing construction
existing_conditions
e.g. good / fair / poor
§ 04P1WO2 — Utility Modification / Sewer Systems
Feeds: P1WO2 (Utility Modification / Sewer Systems)
Service lines need to move
utility_relocation
e.g. yes / no
Sewer work type
sewer_scope
e.g. connect to municipal / new septic install / septic repair / no work
Well work required
well_work
e.g. yes / no
In-ground oil tank present
oil_tank
e.g. yes / no / unknown
§ 05P1WO4 — Site Work
Feeds: P1WO4 (Site Work) · P1WO11 (Gutters & Leaders)
Estimated cubic yards to excavate
cu_yds_excavation
Haul excavation off-site
dirt_removal
e.g. yes / no
Drywell required (drainage / leader connection)
drywell
e.g. yes / no
Lot grade — affects grading cost
lot_slope
e.g. flat / moderate / steep
§ 06P1WO5 — Foundation & Drainage
Feeds: P1WO5 (Foundation & Drainage) · P1WO7 (Roofing)
Foundation scope
foundation_type
e.g. existing / new / repair
Building footprint area / roof plan area (sq ft)
sqft_footprint
Basement or crawl space present
basement
e.g. yes / no / crawl space
Waterproofing required
waterproofing_needed
e.g. yes / no / unknown
§ 07P1WO6 — Framing
Feeds: P1WO6 (Framing) · P1WO9 (Interior Stairs) · P2WO3 (HVAC) · P2WO8 (Drywall)
Conditioned above-grade area (sq ft)
sqft_above_grade
Number of above-grade floors
stories
e.g. 1 / 1.5 / 2 / 3
New addition included in scope
addition
e.g. yes / no
Open floor plan (drives beam complexity)
open_floor_plan
e.g. yes / no
§ 08P1WO7 — Roofing
Feeds: P1WO7 (Roofing)
Roof pitch (slope length multiplier)
pitch
e.g. flat ≤2/12 (1.0) / 4:12 (1.05) / 6:12 (1.12) / 8:12 (1.19) / 12:12 (1.41)
Roof material (cost multiplier)
material
e.g. shingle (1.0) / flat-TPO (0.9) / metal (1.8)
Existing roof to remove
tear_off
e.g. yes / no
§ 09P1WO8 — Windows & Exterior Doors & Garage
Feeds: P1WO8 (Windows & Exterior Doors & Garage)
Estimated number of windows
window_count
Number of exterior doors (not garage)
ext_door_count
Number of garage doors
garage_door_count
Confirmed garage configuration — refines Form 00 placeholder
garage_status
e.g. none / 1-car / 2-car · attached / detached
§ 10P1WO9 — Interior Stairs
Feeds: P1WO9 (Interior Stairs)
Number of interior staircases
staircase_count
Interior stair configuration
stair_type
e.g. straight / L-shaped / U-shaped / winder
§ 11P1WO10 — Siding & Shutters
Feeds: P1WO10 (Siding & Shutters)
Estimated shutter pairs
shutter_count
§ 12P1WO11 — Gutters & Leaders
Feeds: P1WO11 (Gutters & Leaders)
Estimated number of downspouts
leader_count
§ 13P2WO2 — Plumbing
Feeds: P2WO2 (Plumbing) · P3WO2 (Tile Installation) · P3WO12 (Interior Accessories) · P3WO14 (MEP Finishes) · P3WO15 (Shower Glass & Mirrors)
Number of full bathrooms
full_bath_count
Number of half baths / powder rooms
half_bath_count
Number of kitchens (typically 1)
kitchen_count
§ 14P2WO3 — HVAC
Feeds: P2WO3 (HVAC)
Conditioned square footage (for HVAC load)
sqft_conditioned
HVAC scope multiplier
hvac_scope
e.g. repair / replace / new
§ 15P2WO4 — Electrical
Feeds: P2WO4 (Electrical)
Electrical panel upgrade required
panel_upgrade
e.g. yes / no
Electrical service size
service_size
e.g. 100A / 200A / 400A
§ 16P2WO5 — Security & Technology
Feeds: P2WO5 (Security & Technology)
Number of security cameras
camera_count
Low-voltage scope multiplier
low_voltage_scope
e.g. basic / structured-wiring
§ 17P2WO6 — Fireplaces
Feeds: P2WO6 (Fireplaces)
Number of fireplace units
fireplace_count
§ 18P2WO8 — Drywall
Feeds: P2WO8 (Drywall) · P3WO8 (Painting, Wallpaper & Basic Trim)
Drywall scope multiplier
drywall_scope
e.g. patch / partial / full
§ 19P2WO9 — Exterior Carpentry & Masonry
Feeds: P2WO9 (Exterior Carpentry & Masonry)
Deck and porch surface area (sq ft)
deck_sqft
Patio and walkway area (sq ft)
patio_sqft
Exterior railing linear feet (estimate)
ext_railing_lnft
§ 20P2WO10 — Landscape & Grounds
Feeds: P2WO10 (Landscape & Grounds)
Landscape scope multiplier
landscape_scope
e.g. cleanup / improvements / full-renovation
observations not captured above